Cable Work Order WO-2026-000150

admin

WO-2026-000150 — BCL1 N-N000-0001-1250005Y

Bare Copper | IEC | Round/Bunch | IEC 60228 Class 1 | NOT | NOT | 1 x 1.25 mm | Lay NOT | 2.5 mm² · F03 | Alexandria Marine Cable Plant · TEST-CUST-001 | CableDataSheet Test Customer 01
339.686633 kgPlanned Qty
0.000000 kgProduced
1Operations
1Materials
0Drums
PLANNEDStatus
SHOP FLOOR WORK ORDEROverviewSales OrderProduct / CableEngineeringBOM / Product TreeRouting / OperationsMachines / CapacityWorkforceMaterialsDrum / PackagingQuality / TestCosting / Price AnalysisPlanning / CapacityInventory / LogisticsDocumentsApproval / WorkflowProduction FeedbackAudit / History
PRODUCTION WORK ORDER / SHOP FLOOR INSTRUCTION
Frozen Work Order snapshot · Version 1 · Copied 2026-10-04 18:36:38
Included Product Trees: BOM-000004 / Rev.0
Finished Product Code
BCL1 N-N000-0001-1250005Y
Finished Product Name
Bare Copper | IEC | Round/Bunch | IEC 60228 Class 1 | NOT | NOT | 1 x 1.25 mm | Lay NOT | 2.5 mm²
Work Order Quantity
339.686633 kg
Customer
TEST-CUST-001 | CableDataSheet Test Customer 01
Work Order No
WO-2026-000150
Issue / Order Date
2026-10-04
BOM / Recipe Sheet
BOM-000004
Production Date
Production Standard
IEC
Batch / Lot
/
Priority / Status
NORMAL / PLANNED
Order / Production Note
Generated from parent WO-2026-000149 / OP 10 OP020
Snapshot Version
1
Stored Operations
1
Frozen Work Order snapshot is stored.
OP 10
WO-2026-000150-010-OP010-163
OP010
Rod Breakdown / Wire Drawing
Product Tree: BOM-000004 / Rev.0 · Source Seq: 10
Work Centre: |
Machine: F03-M01 | Rod Breakdown Machine
Target Speed: 4 m/min
WO-2026-000150-010-OP010-163
PDF THIS OPERATION PRINT PREVIEW
Planned Production
Start
Finish
Input Quantity
339.686633 kg
Output
|
Output Qty
1000 kg
Process Conditions
Setup
30 min
Machine Duration
15 min
Target Speed
4 m/min
Scrap
1 %
Status
FROZEN
Operation Instructions
—
TECHNICAL / ENGINEERING PARAMETERS
ParameterRequired / TargetMinMaxUnitRemarks
Material TypecopperEngineering Definition Master #35
ConstructionEngineering Definition Master #36
Conductor Stranding TypeEngineering Definition Master #37
Layer Diameters for RollingEngineering Definition Master #38
Lay Direction33Engineering Definition Master #39
Diameter335333Engineering Definition Master #40
Nominal Lay Length33Engineering Definition Master #41
Maximum Lay Length33Engineering Definition Master #42
Theoretical Conductor Resistance33Engineering Definition Master #43
Maximum Conductor Resistance33Engineering Definition Master #44
Maximum Standard Resistance33Engineering Definition Master #45
Material Weight (kg/km)33kg/kmEngineering Definition Master #46
NoteEngineering Definition Master #47
PRODUCTION PROCESS PARAMETERS
ParameterRequired / TargetMinMaxUnitRemarks
Inlet Diameter3333333mm
Outlet Diameter33mm
Line Speed3333333m/min
Annealer Current333333A
QUALITY / TEST PARAMETERS
ParameterRequired / TargetMinMaxUnitRemarks
Conductor Resistance33333ohm/km
Wire Diameter333333333333mm
RAW MATERIALS / COMPONENTS — THIS OPERATION ONLY
Material CodeMaterial NameBOM Qty / OutputCalculated WO QtyUnitMaterial RoleScrap %Notes
BCL1 N-N000-0001-8000012YBare Copper | IEC | Round/Bunch | IEC 60228 Class 1 | NOT | NOT | 1 x 8 mm | Lay NOT | 50 mm²1000343.083499kg1%

Manage Field Options

Only this field is managed here. ADD · EDIT · REMOVE · SAVE without closing the window.

Generic Code Master

This manages the REAL Generic Code master used by Stock Cards. Add / edit / delete unused codes here; no separate Field Option copy.

Add Generic Code

FULL GENERIC CODE MASTER
CodeNameGroupStock CardsActions
CABLEFinished CableCABLE4
IN USE · delete protected
CMP-LSZH-001LSZH Insulation CompoundCOMPOUND1
IN USE · delete protected
CMP-LSZH-002LSZH Sheathing Compound BlackCOMPOUND1
IN USE · delete protected
CMP-PVC-001PVC Insulation CompoundCOMPOUND1
IN USE · delete protected
CMP-PVC-002PVC Sheathing Compound BlackCOMPOUND1
IN USE · delete protected
CMP-RUB-001EPR Rubber Insulation CompoundCOMPOUND1
IN USE · delete protected
CMP-RUB-002CPE Rubber Sheathing CompoundCOMPOUND1
IN USE · delete protected
CMP-XLPE-001XLPE Insulation Compound NaturalCOMPOUND1
IN USE · delete protected
CMP-XLPE-002XLPE Insulation Compound BlackCOMPOUND1
IN USE · delete protected
CMP-XLPE-003XLPE Semiconductive Conductor ScreenCOMPOUND1
IN USE · delete protected
CMP-XLPE-004XLPE Semiconductive Insulation ScreenCOMPOUND1
IN USE · delete protected
CONDUCTORCable ConductorCONDUCTOR5
IN USE · delete protected
GEN-HF-417-REV-7-2015-RANGE-6519HF-417-Rev-7/2015-rangeOther0
GEN-PVC-A-6AACPVC/APVC Compound1
IN USE · delete protected
N/AN/AGENERAL0
PVC/A IEC 60502-1PVC/A IEC 60502-1PVC1
IN USE · delete protected
SEMI-CORESemi Core / Semi-Finished CodeSEMI_CORE1
IN USE · delete protected
SEMI-FINISHED CABLESemi-Finished CableSemi-Finished Cable0
SEMI-FINISHED CORESemi-Finished CoreSemi-Finished Core0
XLPE IEC 60502-1XLPE IEC 60502-1Other1
IN USE · delete protected
XLPE-COMPOUNDXLPE CompoundCOMPOUND1
IN USE · delete protected

Add Selectable Field Option

Save a reusable choice for this data-entry field.
MANAGE ALL FIELD OPTIONS

Quick Attribute Add

Add a missing system attribute without leaving this screen.
NEW ATTRIBUTE — create and map to the detected attribute context.
OPEN ATTRIBUTE MANAGEMENT