Cable Master / Code Generator
adminCable Master / El Sewedy Cable Code Generator
Source: 3.1-El Sewedy Cable Code Generator - 21.01.2026 Rev.0. Each saved cable receives an immutable ERP Cable ID and UUID.
CODE GENERATORCABLE MASTERSTANDARD / SPECIAL CODER STRUCTUREA1–A14 DEFINITIONSRAW EXCEL ARCHIVEUNIT CONVERSIONS
Raw Excel Workbook Archive
Exact non-empty rows from all 15 sheets of the uploaded Rev.0 workbook are stored in the ERP.
ALL SHEETS
EL SEWEDY Standard CODER Rev.0 (29)EL SEWEDY SPECIAL CODER Rev.0 (18)A1-A2 (13)A3 (153)A4 (13)A5 (429)A6 (39)A7 (110)A8 (38)A9 (38)A10 (38)A11 (38)A12 (38)A13 (203)A14 (38)
| Sheet | Row | Raw Values |
|---|---|---|
| A8 | 1 | ["INSULATION",null] |
| A8 | 2 | ["CODE","CODE"] |
| A8 | 3 | ["XLPE","A"] |
| A8 | 4 | ["R-EPR, EI4, 3GI3, EI8, EI7","B"] |
| A8 | 5 | ["R-HEPR","C"] |
| A8 | 6 | ["EI3","D"] |
| A8 | 7 | ["PVC","E"] |
| A8 | 8 | ["XLPO","F"] |
| A8 | 9 | ["PA","G"] |
| A8 | 10 | ["PE","H"] |
| A8 | 11 | [null,"I"] |
| A8 | 12 | ["XL-HFFR","J"] |
| A8 | 13 | ["TPE","K"] |
| A8 | 14 | ["P-EPR","L"] |
| A8 | 15 | ["P-HEPR","M"] |
| A8 | 16 | [null,"N"] |
| A8 | 17 | ["HFFR","O"] |
| A8 | 18 | ["PCP","P"] |
| A8 | 19 | ["FLR-EPR","Q"] |
| A8 | 20 | ["PP","R"] |
| A8 | 21 | ["SHF MUD, SHF2 M-H","S"] |
| A8 | 22 | ["XLPE MV 36 kV","T"] |
| A8 | 23 | ["EPR MV 6/10 kV","U"] |
| A8 | 24 | ["EPR MV 12/20 kV","V"] |
| A8 | 25 | ["EPR MV18/30 kV","W"] |
| A8 | 26 | ["********************","X"] |
| A8 | 27 | ["YOK","Y"] |
| A8 | 28 | ["********************","Z"] |
| A8 | 29 | ["********************","0"] |
| A8 | 30 | ["********************","1"] |
| A8 | 31 | ["P-SHF2","2"] |
| A8 | 32 | ["********************","3"] |
| A8 | 33 | ["********************","4"] |
| A8 | 34 | ["PVC 105","5"] |
| A8 | 35 | ["PU","6"] |
| A8 | 36 | ["********************","7"] |
| A8 | 37 | ["********************","8"] |
| A8 | 38 | ["********************","9"] |
Manage Field Options
Only this field is managed here. ADD · EDIT · REMOVE · SAVE without closing the window.
Generic Code Master
This manages the REAL Generic Code master used by Stock Cards. Add / edit / delete unused codes here; no separate Field Option copy.
Add Generic Code
| Code | Name | Group | Stock Cards | Actions |
|---|---|---|---|---|
| CABLE | Finished Cable | CABLE | 4 |
IN USE · delete protected |
| CMP-LSZH-001 | LSZH Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-LSZH-002 | LSZH Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-001 | PVC Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-002 | PVC Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-001 | EPR Rubber Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-002 | CPE Rubber Sheathing Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-001 | XLPE Insulation Compound Natural | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-002 | XLPE Insulation Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-003 | XLPE Semiconductive Conductor Screen | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-004 | XLPE Semiconductive Insulation Screen | COMPOUND | 1 |
IN USE · delete protected |
| CONDUCTOR | Cable Conductor | CONDUCTOR | 5 |
IN USE · delete protected |
| GEN-HF-417-REV-7-2015-RANGE-6519 | HF-417-Rev-7/2015-range | Other | 0 | |
| GEN-PVC-A-6AAC | PVC/A | PVC Compound | 1 |
IN USE · delete protected |
| N/A | N/A | GENERAL | 0 | |
| PVC/A IEC 60502-1 | PVC/A IEC 60502-1 | PVC | 1 |
IN USE · delete protected |
| SEMI-CORE | Semi Core / Semi-Finished Code | SEMI_CORE | 1 |
IN USE · delete protected |
| SEMI-FINISHED CABLE | Semi-Finished Cable | Semi-Finished Cable | 0 | |
| SEMI-FINISHED CORE | Semi-Finished Core | Semi-Finished Core | 0 | |
| XLPE IEC 60502-1 | XLPE IEC 60502-1 | Other | 1 |
IN USE · delete protected |
| XLPE-COMPOUND | XLPE Compound | COMPOUND | 1 |
IN USE · delete protected |
Add Selectable Field Option
Save a reusable choice for this data-entry field.
Quick Attribute Add
Add a missing system attribute without leaving this screen.