Semi Core Coding System
adminSemi Core Coding System
24-character Semi-Core / Semi-Finished coding system imported from the uploaded CABLEDATASHEET workbook. Variables and selectable values are fully manageable in ERP.
BASE CODE LENGTH: 24
Choose Variable
FIXED24 Position 19–19 · length 1
Add Option
Tape Over Insulation — 36 Options
| Label | Value | Code Fragment | Reserved | Active | Excel Source | Action |
|---|---|---|---|---|---|---|
| PT | PT | A | NO | YES | A19 3 | EDIT |
| 2xMGT/MMGT | 2xMGT/MMGT | M | NO | YES | A19 15 | EDIT |
| MGT/MMGT | MGT/MMGT | N | NO | YES | A19 16 | EDIT |
| YOK | YOK | Y | NO | YES | A19 27 | EDIT |
| Reserved B | ******************** | B | YES | NO | A19 4 | EDIT |
| Reserved C | ******************** | C | YES | NO | A19 5 | EDIT |
| Reserved D | ******************** | D | YES | NO | A19 6 | EDIT |
| Reserved E | ******************** | E | YES | NO | A19 7 | EDIT |
| Reserved F | ******************** | F | YES | NO | A19 8 | EDIT |
| Reserved G | ******************** | G | YES | NO | A19 9 | EDIT |
| Reserved H | ******************** | H | YES | NO | A19 10 | EDIT |
| Reserved I | ******************** | I | YES | NO | A19 11 | EDIT |
| Reserved J | ******************** | J | YES | NO | A19 12 | EDIT |
| Reserved K | ******************** | K | YES | NO | A19 13 | EDIT |
| Reserved L | ******************** | L | YES | NO | A19 14 | EDIT |
| Reserved O | ******************** | O | YES | NO | A19 17 | EDIT |
| Reserved P | ******************** | P | YES | NO | A19 18 | EDIT |
| Reserved Q | ******************** | Q | YES | NO | A19 19 | EDIT |
| Reserved R | ******************** | R | YES | NO | A19 20 | EDIT |
| Reserved S | ******************** | S | YES | NO | A19 21 | EDIT |
| Reserved T | ******************** | T | YES | NO | A19 22 | EDIT |
| Reserved U | ******************** | U | YES | NO | A19 23 | EDIT |
| Reserved V | ******************** | V | YES | NO | A19 24 | EDIT |
| Reserved W | ******************** | W | YES | NO | A19 25 | EDIT |
| Reserved X | ******************** | X | YES | NO | A19 26 | EDIT |
| Reserved Z | ******************** | Z | YES | NO | A19 28 | EDIT |
| Reserved 0 | ******************** | 0 | YES | NO | A19 29 | EDIT |
| Reserved 1 | ******************** | 1 | YES | NO | A19 30 | EDIT |
| Reserved 2 | ******************** | 2 | YES | NO | A19 31 | EDIT |
| Reserved 3 | ******************** | 3 | YES | NO | A19 32 | EDIT |
| Reserved 4 | ******************** | 4 | YES | NO | A19 33 | EDIT |
| Reserved 5 | ******************** | 5 | YES | NO | A19 34 | EDIT |
| Reserved 6 | ******************** | 6 | YES | NO | A19 35 | EDIT |
| Reserved 7 | ******************** | 7 | YES | NO | A19 36 | EDIT |
| Reserved 8 | ******************** | 8 | YES | NO | A19 37 | EDIT |
| Reserved 9 | ******************** | 9 | YES | NO | A19 38 | EDIT |
Manage Field Options
Only this field is managed here. ADD · EDIT · REMOVE · SAVE without closing the window.
Generic Code Master
This manages the REAL Generic Code master used by Stock Cards. Add / edit / delete unused codes here; no separate Field Option copy.
Add Generic Code
| Code | Name | Group | Stock Cards | Actions |
|---|---|---|---|---|
| CABLE | Finished Cable | CABLE | 4 |
IN USE · delete protected |
| CMP-LSZH-001 | LSZH Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-LSZH-002 | LSZH Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-001 | PVC Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-002 | PVC Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-001 | EPR Rubber Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-002 | CPE Rubber Sheathing Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-001 | XLPE Insulation Compound Natural | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-002 | XLPE Insulation Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-003 | XLPE Semiconductive Conductor Screen | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-004 | XLPE Semiconductive Insulation Screen | COMPOUND | 1 |
IN USE · delete protected |
| CONDUCTOR | Cable Conductor | CONDUCTOR | 5 |
IN USE · delete protected |
| GEN-HF-417-REV-7-2015-RANGE-6519 | HF-417-Rev-7/2015-range | Other | 0 | |
| GEN-PVC-A-6AAC | PVC/A | PVC Compound | 1 |
IN USE · delete protected |
| N/A | N/A | GENERAL | 0 | |
| PVC/A IEC 60502-1 | PVC/A IEC 60502-1 | PVC | 1 |
IN USE · delete protected |
| SEMI-CORE | Semi Core / Semi-Finished Code | SEMI_CORE | 1 |
IN USE · delete protected |
| SEMI-FINISHED CABLE | Semi-Finished Cable | Semi-Finished Cable | 0 | |
| SEMI-FINISHED CORE | Semi-Finished Core | Semi-Finished Core | 0 | |
| XLPE IEC 60502-1 | XLPE IEC 60502-1 | Other | 1 |
IN USE · delete protected |
| XLPE-COMPOUND | XLPE Compound | COMPOUND | 1 |
IN USE · delete protected |
Add Selectable Field Option
Save a reusable choice for this data-entry field.
Quick Attribute Add
Add a missing system attribute without leaving this screen.