Semi Core Coding System
adminSemi Core Coding System
24-character Semi-Core / Semi-Finished coding system imported from the uploaded CABLEDATASHEET workbook. Variables and selectable values are fully manageable in ERP.
BASE CODE LENGTH: 24
Edit Variable
24-digit protection: use METADATA for extra variables that must not change the 24-character code. Use APPEND only when you intentionally want extra coded characters after position 24. FIXED24 variables cannot overlap existing positions.
Variable Rules
FIXED24: occupies exact positions inside the original 24-character code.
METADATA: extra business/technical variable; unlimited additional variables can be added without changing the 24-character code.
APPEND: adds a coded extension after character 24. Use only when you intentionally create a longer code.
| Order | Key | Variable | Mode | Position | Length | Required | Active | Source | Action |
|---|---|---|---|---|---|---|---|---|---|
| 10 | A1_2 | Semi-Finished Group Code YARIMAMUL GRUP KODU | FIXED24 | 1 | 2 | YES | YES | A1-2 | EDIT OPTIONS |
| 20 | A3_5 | Cable Type KABLO TIPI | FIXED24 | 3 | 3 | YES | YES | A3-4-5 | EDIT OPTIONS |
| 30 | A6 | Blank / Separator BLANK / AYIRICI | FIXED24 | 6 | 1 | YES | YES | A6 | EDIT OPTIONS |
| 40 | A7_8 | Conductor Cross-Section İLETKEN KESİT | FIXED24 | 7 | 2 | YES | YES | A7-8 | EDIT OPTIONS |
| 50 | A9_10 | Conductor İLETKEN | FIXED24 | 9 | 2 | YES | YES | A9-10 | EDIT OPTIONS |
| 60 | A11 | Tape Over Conductor İLETKEN ÜZERİ BANT | FIXED24 | 11 | 1 | YES | YES | A11 | EDIT OPTIONS |
| 70 | A12 | Insulation 1 İZOLE1 | FIXED24 | 12 | 1 | YES | YES | A12 | EDIT OPTIONS |
| 80 | A13 | Insulation 2 İZOLE2 | FIXED24 | 13 | 1 | YES | YES | A13 | EDIT OPTIONS |
| 90 | A14_16 | Insulation Wall Thickness İZOLE ET KALINLIĞI | FIXED24 | 14 | 3 | YES | YES | A14-15-16 | EDIT OPTIONS |
| 100 | A17_18 | Insulation Colour İZOLE RENGİ | FIXED24 | 17 | 2 | YES | YES | A17-18 | EDIT OPTIONS |
| 110 | A19 | Tape Over Insulation İZOLE ÜZERİ BANT | FIXED24 | 19 | 1 | YES | YES | A19 | EDIT OPTIONS |
| 120 | A20 | Metallic Screen Over PTQ PTQ ÜZERİ METALİK EKRAN | FIXED24 | 20 | 1 | YES | YES | A20 | EDIT OPTIONS |
| 130 | A21 | Sheath Over PTQ PTQ ÜZERİ KILIF | FIXED24 | 21 | 1 | YES | YES | A21 | EDIT OPTIONS |
| 140 | A22 | Outer Sheath / Colour VARSA KILIF ve RENGİ | FIXED24 | 22 | 1 | YES | YES | A22 | EDIT OPTIONS |
| 150 | A23_24 | Standard STANDART | FIXED24 | 23 | 2 | YES | YES | A23-24 | EDIT OPTIONS |
Manage Field Options
Only this field is managed here. ADD · EDIT · REMOVE · SAVE without closing the window.
Generic Code Master
This manages the REAL Generic Code master used by Stock Cards. Add / edit / delete unused codes here; no separate Field Option copy.
Add Generic Code
| Code | Name | Group | Stock Cards | Actions |
|---|---|---|---|---|
| CABLE | Finished Cable | CABLE | 4 |
IN USE · delete protected |
| CMP-LSZH-001 | LSZH Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-LSZH-002 | LSZH Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-001 | PVC Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-002 | PVC Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-001 | EPR Rubber Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-002 | CPE Rubber Sheathing Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-001 | XLPE Insulation Compound Natural | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-002 | XLPE Insulation Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-003 | XLPE Semiconductive Conductor Screen | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-004 | XLPE Semiconductive Insulation Screen | COMPOUND | 1 |
IN USE · delete protected |
| CONDUCTOR | Cable Conductor | CONDUCTOR | 5 |
IN USE · delete protected |
| GEN-HF-417-REV-7-2015-RANGE-6519 | HF-417-Rev-7/2015-range | Other | 0 | |
| GEN-PVC-A-6AAC | PVC/A | PVC Compound | 1 |
IN USE · delete protected |
| N/A | N/A | GENERAL | 0 | |
| PVC/A IEC 60502-1 | PVC/A IEC 60502-1 | PVC | 1 |
IN USE · delete protected |
| SEMI-CORE | Semi Core / Semi-Finished Code | SEMI_CORE | 1 |
IN USE · delete protected |
| SEMI-FINISHED CABLE | Semi-Finished Cable | Semi-Finished Cable | 0 | |
| SEMI-FINISHED CORE | Semi-Finished Core | Semi-Finished Core | 0 | |
| XLPE IEC 60502-1 | XLPE IEC 60502-1 | Other | 1 |
IN USE · delete protected |
| XLPE-COMPOUND | XLPE Compound | COMPOUND | 1 |
IN USE · delete protected |
Add Selectable Field Option
Save a reusable choice for this data-entry field.
Quick Attribute Add
Add a missing system attribute without leaving this screen.