Operation & Parameter Master
adminOperation & Parameter Master
Main list of cable-production operations. Operation Parameters are managed in Engineering. Machine Parameters are managed on Machine Cards.
New OperationClick to expand
New Operation
OP140 — Outer Sheath Extrusion
Machine-specific definitions override/fill the parameter list used by BOM. Operation-default definitions are fallback when no machine-specific definition exists.
Add ENGINEERING Parameter
ENGINEERING — Machine Definitions
| Code | Name | Unit | Type | Default | Min/Max | Required | |
|---|---|---|---|---|---|---|---|
| X_P | Process Type | text | / | ||||
| X_MS | Material Standard | text | / | ||||
| X_R | Color | text | / | ||||
| X_BO | Color Masterbatch Ratio (%) | % | number | / | |||
| X_BT | Color Masterbatch Type | text | / | ||||
| X_KO | Catalyst Ratio (%) | % | number | / | |||
| X_RKO | Anti-Rodent Additive Ratio (%) | % | number | / | |||
| X_TKO | Anti-Termite Additive Ratio (%) | % | number | / | |||
| X_FKO | Flame-Retardant Additive Ratio (%) | % | number | / | |||
| X_KKO | Foaming Additive Ratio (%) | % | number | / | |||
| X_NET | Nominal Wall Thickness (mm) | mm | number | / | |||
| X_NMET | Minimum Point Wall Thickness (mm) | mm | number | / | |||
| X_NOMC | Nominal Diameter (mm) | mm | number | / | |||
| X_MINC | Minimum Diameter (mm) | mm | number | / | |||
| X_MAXC | Maximum Diameter (mm) | mm | number | / | |||
| X_IET | Manufacturing Wall Thickness (mm) | mm | number | / | |||
| X_IMIT | Manufacturing Minimum Wall Thickness (mm) | mm | number | / | |||
| X_IMAT | Manufacturing Maximum Wall Thickness (mm) | mm | number | / | |||
| X_MA | Material Weight (kg/km) | kg/km | number | / | |||
| X_INOMC | Manufacturing Nominal Diameter (mm) | mm | number | / | |||
| X_IMINC | Manufacturing Minimum Diameter (mm) | mm | number | / | |||
| X_IMAXC | Manufacturing Maximum Diameter (mm) | mm | number | / | |||
| J_P | Process Type | text | / | ||||
| J_MS | Material Standard | text | / | ||||
| J_R | Color | text | / | ||||
| J_BO | Color Masterbatch Ratio (%) | % | number | / | |||
| J_BT | Color Masterbatch Type | text | / | ||||
| J_KO | Catalyst Ratio (%) | % | number | / | |||
| J_RKO | Anti-Rodent Additive Ratio (%) | % | number | / | |||
| J_TKO | Anti-Termite Additive Ratio (%) | % | number | / | |||
| J_FKO | Flame-Retardant Additive Ratio (%) | % | number | / | |||
| J_KKO | Foaming Additive Ratio (%) | % | number | / | |||
| J_GC | Input Diameter | number | / | ||||
| J_NOMC | Nominal Diameter (mm) | mm | number | / | |||
| J_MINC | Minimum Diameter (mm) | mm | number | / | |||
| J_MAXC | Maximum Diameter (mm) | mm | number | / | |||
| J_IET | Manufacturing Wall Thickness (mm) | mm | number | / | |||
| J_IMIT | Manufacturing Minimum Wall Thickness (mm) | mm | number | / | |||
| J_IMAT | Manufacturing Maximum Wall Thickness (mm) | mm | number | / | |||
| J_MA | Material Weight (kg/km) | kg/km | number | / | |||
| J_SMIC | Standard Minimum Diameter | number | / | ||||
| J_SMAC | Standard Maximum Diameter | number | / | ||||
| J_NOT | Jacket Note | text | / | ||||
| J_SMIT | Standard Minimum Wall Thickness (mm) | mm | number | / | |||
| J_SMAT | Standard Maximum Wall Thickness (mm) | mm | number | / | |||
| O_MAR | Marking | text | / |
Operation Default Fallback
| Group | Code | Name | Unit | Default |
|---|---|---|---|---|
| ENGINEERING | X_P | Process Type | ||
| ENGINEERING | X_MS | Material Standard | ||
| ENGINEERING | X_R | Color | ||
| ENGINEERING | X_BO | Color Masterbatch Ratio (%) | % | |
| ENGINEERING | X_BT | Color Masterbatch Type | ||
| ENGINEERING | X_KO | Catalyst Ratio (%) | % | |
| ENGINEERING | X_RKO | Anti-Rodent Additive Ratio (%) | % | |
| ENGINEERING | X_TKO | Anti-Termite Additive Ratio (%) | % | |
| ENGINEERING | X_FKO | Flame-Retardant Additive Ratio (%) | % | |
| ENGINEERING | TARGET_OD | Final Target OD | mm | |
| ENGINEERING | X_KKO | Foaming Additive Ratio (%) | % | |
| ENGINEERING | SHEATH_THICKNESS | Nominal Sheath Thickness | mm | |
| ENGINEERING | PRINT_LEGEND | Printing / Marking | ||
| ENGINEERING | X_NET | Nominal Wall Thickness (mm) | mm | |
| ENGINEERING | X_NMET | Minimum Point Wall Thickness (mm) | mm | |
| ENGINEERING | X_NOMC | Nominal Diameter (mm) | mm | |
| ENGINEERING | X_MINC | Minimum Diameter (mm) | mm | |
| ENGINEERING | X_MAXC | Maximum Diameter (mm) | mm | |
| ENGINEERING | X_IET | Manufacturing Wall Thickness (mm) | mm | |
| ENGINEERING | X_IMIT | Manufacturing Minimum Wall Thickness (mm) | mm | |
| ENGINEERING | X_IMAT | Manufacturing Maximum Wall Thickness (mm) | mm | |
| ENGINEERING | X_MA | Material Weight (kg/km) | kg/km | |
| ENGINEERING | X_INOMC | Manufacturing Nominal Diameter (mm) | mm | |
| ENGINEERING | X_IMINC | Manufacturing Minimum Diameter (mm) | mm | |
| ENGINEERING | X_IMAXC | Manufacturing Maximum Diameter (mm) | mm | |
| ENGINEERING | J_P | Process Type | ||
| ENGINEERING | J_MS | Material Standard | ||
| ENGINEERING | J_R | Color | ||
| ENGINEERING | J_BO | Color Masterbatch Ratio (%) | % | |
| ENGINEERING | J_BT | Color Masterbatch Type | ||
| ENGINEERING | J_KO | Catalyst Ratio (%) | % | |
| ENGINEERING | J_RKO | Anti-Rodent Additive Ratio (%) | % | |
| ENGINEERING | J_TKO | Anti-Termite Additive Ratio (%) | % | |
| ENGINEERING | J_FKO | Flame-Retardant Additive Ratio (%) | % | |
| ENGINEERING | J_KKO | Foaming Additive Ratio (%) | % | |
| ENGINEERING | J_GC | Input Diameter | ||
| ENGINEERING | J_NOMC | Nominal Diameter (mm) | mm | |
| ENGINEERING | J_MINC | Minimum Diameter (mm) | mm | |
| ENGINEERING | J_MAXC | Maximum Diameter (mm) | mm | |
| ENGINEERING | J_IET | Manufacturing Wall Thickness (mm) | mm | |
| ENGINEERING | J_IMIT | Manufacturing Minimum Wall Thickness (mm) | mm | |
| ENGINEERING | J_IMAT | Manufacturing Maximum Wall Thickness (mm) | mm | |
| ENGINEERING | J_MA | Material Weight (kg/km) | kg/km | |
| ENGINEERING | J_SMIC | Standard Minimum Diameter | ||
| ENGINEERING | J_SMAC | Standard Maximum Diameter | ||
| ENGINEERING | J_NOT | Jacket Note | ||
| ENGINEERING | J_SMIT | Standard Minimum Wall Thickness (mm) | mm | |
| ENGINEERING | J_SMAT | Standard Maximum Wall Thickness (mm) | mm | |
| ENGINEERING | O_MAR | Marking | ||
| QUALITY | FINAL_OD | Final Cable OD | mm | |
| QUALITY | MIN_THICKNESS | Minimum Thickness | mm | |
| QUALITY | SPARK_TEST | Spark Test Voltage | kV | |
| PROCESS | ZONE_TEMPERATURES | Extruder Zone Temperatures | °C | |
| PROCESS | LINE_SPEED | Line Speed | m/min |
Manage Field Options
Only this field is managed here. ADD · EDIT · REMOVE · SAVE without closing the window.
Generic Code Master
This manages the REAL Generic Code master used by Stock Cards. Add / edit / delete unused codes here; no separate Field Option copy.
Add Generic Code
| Code | Name | Group | Stock Cards | Actions |
|---|---|---|---|---|
| CABLE | Finished Cable | CABLE | 4 |
IN USE · delete protected |
| CMP-LSZH-001 | LSZH Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-LSZH-002 | LSZH Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-001 | PVC Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-PVC-002 | PVC Sheathing Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-001 | EPR Rubber Insulation Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-RUB-002 | CPE Rubber Sheathing Compound | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-001 | XLPE Insulation Compound Natural | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-002 | XLPE Insulation Compound Black | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-003 | XLPE Semiconductive Conductor Screen | COMPOUND | 1 |
IN USE · delete protected |
| CMP-XLPE-004 | XLPE Semiconductive Insulation Screen | COMPOUND | 1 |
IN USE · delete protected |
| CONDUCTOR | Cable Conductor | CONDUCTOR | 5 |
IN USE · delete protected |
| GEN-HF-417-REV-7-2015-RANGE-6519 | HF-417-Rev-7/2015-range | Other | 0 | |
| GEN-PVC-A-6AAC | PVC/A | PVC Compound | 1 |
IN USE · delete protected |
| N/A | N/A | GENERAL | 0 | |
| PVC/A IEC 60502-1 | PVC/A IEC 60502-1 | PVC | 1 |
IN USE · delete protected |
| SEMI-CORE | Semi Core / Semi-Finished Code | SEMI_CORE | 1 |
IN USE · delete protected |
| SEMI-FINISHED CABLE | Semi-Finished Cable | Semi-Finished Cable | 0 | |
| SEMI-FINISHED CORE | Semi-Finished Core | Semi-Finished Core | 0 | |
| XLPE IEC 60502-1 | XLPE IEC 60502-1 | Other | 1 |
IN USE · delete protected |
| XLPE-COMPOUND | XLPE Compound | COMPOUND | 1 |
IN USE · delete protected |
Add Selectable Field Option
Save a reusable choice for this data-entry field.
Quick Attribute Add
Add a missing system attribute without leaving this screen.