Engineering Formula Library — Batch Furnace Annealing
This library documents the equations actually used by the calculation engine. Some computed fields are direct model outputs rather than independent closed-form equations. Assumptions must be calibrated before production use.
Wire cross-section
A = π d² / 4
Variables and SI units: A [m²], d [m]
Derivation / calculation: Circular cross-sectional area; diameter is converted from millimetres to metres.
Assumptions and limitations: Round solid wire; not a stranded conductor equivalent area.
Reference / physical basis: Geometry (Euclidean circle).
Specific enthalpy rise
Δh = ∫(T₀ to T₁) cp(T) dT = cp20(T₁−T₀) + b/2 [(T₁−20)²−(T₀−20)²]
Variables and SI units: Δh [J/kg], cp20 [J/(kg K)], b [J/(kg K²)], T [°C]
Derivation / calculation: Integrate the implemented linear heat-capacity approximation cp(T)=cp20+b(T−20).
Assumptions and limitations: Approximate coefficients; not certified temperature-dependent property tables. No latent heat.
Reference / physical basis: First law of thermodynamics; model implementation Annealing energy model.
Programmed furnace temperature
Tset(t) = min(Ttarget, T0 + βt/3600); tramp = 3600(Ttarget−T0)/β
Variables and SI units: t [s], β [°C/h], tramp [s]
Derivation / calculation: Linear programmed ramp followed by a fixed-temperature hold.
Assumptions and limitations: Setpoint is not actual furnace or coil temperature.
Reference / physical basis: Process control ramp definition.
Coil surface and core balances
Cs dTs/dt = Hfs(Tf−Ts)−Hsc(Ts−Tc); Cc dTc/dt = Hsc(Ts−Tc)
Variables and SI units: Cs,Cc [J/K], Hfs,Hsc [W/K], T [°C]
Derivation / calculation: First-law balance for two lumped coil thermal masses; C=mass fraction × cp(T).
Assumptions and limitations: H coefficients and mass fraction require instrumented trials; not calculated from coil dimensions.
Reference / physical basis: Lumped-capacitance thermal network.
Furnace atmosphere/structure balance
Cf dTf/dt = ηPin − Hfs(Tf−Ts) − Hfix(Tf−Tfix) − UA(Tf−Ta)
Variables and SI units: Cf [J/K], η [1], Pin [W], UA,H [W/K]
Derivation / calculation: Conservation of energy including heater input, coil exchange, fixture exchange and ambient losses.
Assumptions and limitations: Effective lumped capacity; no airflow, gas enthalpy or spatial wall gradients.
Reference / physical basis: First law of thermodynamics.
Fixture energy balance
Cfix dTfix/dt = Hfix(Tf−Tfix); Hfix = 0.12 Hfs (assumed)
Variables and SI units: Cfix [J/K], Hfix [W/K]
Derivation / calculation: One-node thermal balance for baskets and fixtures.
Assumptions and limitations: 0.12 is an illustrative assumption, NOT a measured universal constant.
Reference / physical basis: Lumped thermal network; implementation assumption.
Heater control and consumption
Pin = min(Prated, max(0, Prequested)); Eelec = ∫Pin dt / 3.6×10⁶
Variables and SI units: Pin,Prated [W], Eelec [kWh]
Derivation / calculation: Power-limited setpoint-following controller; sum power over numerical time steps.
Assumptions and limitations: Controller is simplified; no PID, hysteresis or cooling phase.
Reference / physical basis: Power-energy identity; Annealing energy model furnace().
Cold-point attainment
tcore = first simulated time where Tc ≥ Tcore,target
Variables and SI units: tcore [s or min], Tc [°C]
Derivation / calculation: Search time-history of simulated core temperature for threshold crossing.
Assumptions and limitations: Two-zone core is a proxy for coldest point, not validated worst-case position.
Reference / physical basis: Transient temperature simulation.
Ideal wire energy
Eideal = mw Δh / 3.6×10⁶
Variables and SI units: mw [kg], Δh [J/kg], Eideal [kWh]
Derivation / calculation: Multiply mass by enthalpy rise and convert J to kWh.
Assumptions and limitations: Excludes furnace mass, heat losses, fixtures and hold energy.
Reference / physical basis: First law of thermodynamics.
Calculation expressions currently in use
These saved expressions drive the numerical model. Variables use SI units unless specified by the corresponding formula.
Download complete formula documentation (Markdown)
Prepared by CableDataSheet · Not a machine setpoint recommendation · Verify with thermocouples, machine limits and mechanical/electrical tests.