PROCESS ENGINEERING · COPPER & ALUMINIUM

Annealing Calculator

Model inline wire annealing and batch furnace heating. Review temperatures, electrical demand and the equations behind each result.

● Theoretical model · Calibration required

How this engineering calculator works

01 Select process Choose inline electrical annealing or batch furnace heating.
02 Enter parameters Change the measured or calibrated inputs. Each field explains its meaning.
03 Run simulation The energy-balance model calculates heating, electrical demand and the temperature profile.
04 Review and verify Inspect plots, formulas, assumptions, and warnings before using any result.

Configure your process

Engineering Formula Library · Every equation includes units, derivation, limitations and references.

Batch furnace thermal model

FURNACE ATMOSPHERE / STRUCTURE Coil surface Coil core Heater power Ambient loss Fixtures absorb heat as a separate thermal node

Furnace, coil surface, coil core and fixtures are separate thermal nodes. The programmed hold begins after the ramp; the result separately reports whether the core target was reached.

Engineering Formula Library — Batch Furnace Annealing

This library documents the equations actually used by the calculation engine. Some computed fields are direct model outputs rather than independent closed-form equations. Assumptions must be calibrated before production use.

Wire cross-section

A = π d² / 4

Variables and SI units: A [m²], d [m]

Derivation / calculation: Circular cross-sectional area; diameter is converted from millimetres to metres.

Assumptions and limitations: Round solid wire; not a stranded conductor equivalent area.

Reference / physical basis: Geometry (Euclidean circle).

Specific enthalpy rise

Δh = ∫(T₀ to T₁) cp(T) dT = cp20(T₁−T₀) + b/2 [(T₁−20)²−(T₀−20)²]

Variables and SI units: Δh [J/kg], cp20 [J/(kg K)], b [J/(kg K²)], T [°C]

Derivation / calculation: Integrate the implemented linear heat-capacity approximation cp(T)=cp20+b(T−20).

Assumptions and limitations: Approximate coefficients; not certified temperature-dependent property tables. No latent heat.

Reference / physical basis: First law of thermodynamics; model implementation Annealing energy model.

Programmed furnace temperature

Tset(t) = min(Ttarget, T0 + βt/3600); tramp = 3600(Ttarget−T0)/β

Variables and SI units: t [s], β [°C/h], tramp [s]

Derivation / calculation: Linear programmed ramp followed by a fixed-temperature hold.

Assumptions and limitations: Setpoint is not actual furnace or coil temperature.

Reference / physical basis: Process control ramp definition.

Coil surface and core balances

Cs dTs/dt = Hfs(Tf−Ts)−Hsc(Ts−Tc); Cc dTc/dt = Hsc(Ts−Tc)

Variables and SI units: Cs,Cc [J/K], Hfs,Hsc [W/K], T [°C]

Derivation / calculation: First-law balance for two lumped coil thermal masses; C=mass fraction × cp(T).

Assumptions and limitations: H coefficients and mass fraction require instrumented trials; not calculated from coil dimensions.

Reference / physical basis: Lumped-capacitance thermal network.

Furnace atmosphere/structure balance

Cf dTf/dt = ηPin − Hfs(Tf−Ts) − Hfix(Tf−Tfix) − UA(Tf−Ta)

Variables and SI units: Cf [J/K], η [1], Pin [W], UA,H [W/K]

Derivation / calculation: Conservation of energy including heater input, coil exchange, fixture exchange and ambient losses.

Assumptions and limitations: Effective lumped capacity; no airflow, gas enthalpy or spatial wall gradients.

Reference / physical basis: First law of thermodynamics.

Fixture energy balance

Cfix dTfix/dt = Hfix(Tf−Tfix); Hfix = 0.12 Hfs (assumed)

Variables and SI units: Cfix [J/K], Hfix [W/K]

Derivation / calculation: One-node thermal balance for baskets and fixtures.

Assumptions and limitations: 0.12 is an illustrative assumption, NOT a measured universal constant.

Reference / physical basis: Lumped thermal network; implementation assumption.

Heater control and consumption

Pin = min(Prated, max(0, Prequested)); Eelec = ∫Pin dt / 3.6×10⁶

Variables and SI units: Pin,Prated [W], Eelec [kWh]

Derivation / calculation: Power-limited setpoint-following controller; sum power over numerical time steps.

Assumptions and limitations: Controller is simplified; no PID, hysteresis or cooling phase.

Reference / physical basis: Power-energy identity; Annealing energy model furnace().

Cold-point attainment

tcore = first simulated time where Tc ≥ Tcore,target

Variables and SI units: tcore [s or min], Tc [°C]

Derivation / calculation: Search time-history of simulated core temperature for threshold crossing.

Assumptions and limitations: Two-zone core is a proxy for coldest point, not validated worst-case position.

Reference / physical basis: Transient temperature simulation.

Ideal wire energy

Eideal = mw Δh / 3.6×10⁶

Variables and SI units: mw [kg], Δh [J/kg], Eideal [kWh]

Derivation / calculation: Multiply mass by enthalpy rise and convert J to kWh.

Assumptions and limitations: Excludes furnace mass, heat losses, fixtures and hold energy.

Reference / physical basis: First law of thermodynamics.

Calculation expressions currently in use

These saved expressions drive the numerical model. Variables use SI units unless specified by the corresponding formula.

Cp cp20+cpSlope*(T-reference_C)
Enthalpy cp20*(T1-T0)+cpSlope*((T1-reference_C)^2-(T0-reference_C)^2)/2
Resistivity res20*(1+alpha*(T-reference_C))
Area pi*d*d/4
Perimeter pi*d
Mass Flow density*A*v
Joule Per M I*I*rho/A
Convection Per M h*perimeter*(T-Ta)
Radiation Per M emissivity*sigma*perimeter*((T+kelvin_offset)^4-(Ta+kelvin_offset)^4)
Wire Delta (joule-convection-radiation)*dx/(mass_flow*cp)
Residence Increment dx/(mass_flow/(density*A))
Voltage Increment I*rho*dx/A
Metal Heat mass_flow*enthalpy
Ramp Time (target-initial)/ramp*s_per_hour
Setpoint min(target,initial+ramp*t/s_per_hour)
Surface Capacity mass*fraction*cp
Core Capacity mass*(1-fraction)*cp
Fixture Capacity max(minimum_capacity,mass*cp)
Exchange H*(T1-T2)
Fixture Exchange if(mass>0,H*fixture_exchange_fraction*(Tf-Tfix),0)
Requested Power max(0,(setpoint-Tf)*capacity/max(dt,time_epsilon)+qfs+qfix+loss)
Furnace Delta (heater-qfs-qfix-loss)*dt/capacity
Surface Delta (qfs-qsc)*dt/capacity
Node Delta q*dt/capacity
Joules To KWh energy/J_per_kWh
Wire Specific power/mass_flow/J_per_kWh
Mass Specific energy/J_per_kWh/mass
Ideal Energy mass*enthalpy/J_per_kWh
Kinetics k0*exp(-Q/(gas_R*(T+kelvin_offset)))
Fraction 1-exp(-(k*time)^n)

Download complete formula documentation (Markdown)

Prepared by CableDataSheet · Not a machine setpoint recommendation · Verify with thermocouples, machine limits and mechanical/electrical tests.