Copper Annealing Calculator
Enter copper diameter, target elongation and tensile strength to find matching tested speeds and annealing voltages.
Speed, voltage & energy
Enter targetsProduction test data required
Add measured production tests to connect diameter and mechanical properties to speed and voltage. No test data has been supplied with this calculator.
Download test-data template ↓How the matching and energy calculation work
Same setup, measured properties
Only recorded test runs are matched. Results are not interpolated between diameters, machines or material conditions. The first match is the fastest recorded run inside all selected tolerances; it is not a predicted maximum production speed.
A profile identifies the machine, copper grade, drawing history, cooling setup, elongation gauge length and voltage measurement basis. Use a separate profile when those conditions change.
Required energy
Energy (kWh) = measured power (kW) × length (m) / speed (m/min) / 60Energy is calculated from the selected run’s measured active input power and speed. It assumes steady running; it excludes startup energy and loads outside that power measurement.
If a test has no measured active input power, its speed and voltage can still be shown, but its energy remains unavailable.
Test data
Import measured production records from the Annealing admin page. The CSV template contains column names only.
Download test-data CSV template · Manage production tests