• Welcome to CableDataSheet, Cable and Wire Technical Consulting Service.
 

News:

You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
Tacettin İKİZ



Main Menu

UNE 22510 Cable Code Designation

Started by tacettin, April 05, 2024, 03:51:00 PM

Previous topic - Next topic

tacettin

UNE 22510 Cable Code Designation

1st Isolation:

V = Polyvinyl chloride (PVC) insulation.
D = Ethylene propylene (EPR) insulation.
R = Cross-linked polyethylene (XLPE) insulation

2nd Screens

–Screens for rigid cables:

H = Cables with semiconductor screen on the conductor and on the insulation and individual metal screen.

Safety screens for flexible cables and armored flexible cables:

S1 = Screen of semiconductor mixture extruded on the insulation of each active conductor and drains. rrespondents.
S2 = Semiconductor mixture screen extruded on the set of wired conductors and drains. rrespondents.
H1 = Metal screen placed over the insulation of each active conductor.
0 = Joint metal screen.

3rd Metal protections:

M = Normalized armor of galvanized steel wires.
M1 = Special armor made of galvanized steel wires.
M2 = Galvanized steel cable armor.
MV = Galvanized steel wire armor individually coated with PVC.

4th Sealing and exterior cover:

N = Polychloroprene or similar (PCP).
V = Polyvinyl chloride (PVC).

K    = Compact circular copper rope.
K – AL = Compact aluminum circular rope.
F    = Flexible rope.

Designation examples

a)    Designation of a rigid armored cable (see UNE 22511 Standard), of the following composition:
–    Three compacted copper conductors (K) with a circular section of 95 mm2    .
–    Polyvinyl chloride (V) insulation.
–    Polyvinyl chloride (V) sealing cover.
–    Steel wire armor (M).
–    Polyvinyl chloride (V) outer cover.
–    Nominal cable voltage U0/U = 3.6/6 kV.

VVMV 3.6/6 kV (3x95) K

b)    Designation of a rigid, armored cable (see UNE 22511 Standard) of the following composition:
–    Three compacted copper conductors (K) with a circular section of 50 mm2 –    .
One protective conductor (provision "a", section 5.1) of 25 mm2 – Polyvinyl    .
chloride insulation (V).
–    Polyvinyl chloride (V) sealing cover.
–    Steel wire armor (M).
–    Polyvinyl chloride (V) outer cover.
–    Nominal cable voltage U0/U = 0.6/1 kV.

VVMV 0,6/1 kV (3x50+ 1x25) K

c)    Designation of a rigid armored cable (see UNE 22511 Standard) of the following composition:
–    Three compacted copper conductors (K) with a circular section of 50 mm2 –    .
One 25 mm2 pilot conductor –    .
Polyvinyl chloride insulation (V).
–    Steel wire armor (M).
–    Polyvinyl chloride (V) outer cover.
–    Nominal cable voltage U0/U = 0.6/1 kV.

VVMV 0,6/1 kV (3x50+ 1x25 P) K

d)    Designation of an armored flexible cable (see UNE 22512 Standard) of the following composition:
–    Three 95 mm2 (F) flexible copper conductors .
–    Protective conductor (provision "d", section 5.1) based on three 16 mm2 flexible conductors    .
–    Ethylene propylene insulation (D).
–    Armor of galvanized steel wire cables (M2).
–    Outer cover of polychloroprene or similar (N).
–    Nominal cable voltage U0/U = 0.6/1 kV.

DM2N 0,6/1 kV (3x95+ 3x16) F

e)    Designation of an armored flexible cable (see UNE 22512 Standard) of the following composition:
–    Three 50 mm2 (F) flexible copper conductors .
–    Protective conductor (provision "d", section 5.1) based on three 10 mm2 flexible conductors – Three 4 .
mm2 pilot conductors    .
–    Ethylene propylene insulation (D).
–    Armor of galvanized steel wire cables (M2).
–    Outer cover of polychloroprene or similar (N).
–    Nominal cable voltage U0/U = 0.6/1 kV.

DM2N 0,6/1 kV (3x50+ 3x10+ 3x4 P) F

f)    Designation of a flexible cable (see UNE 22513-2 Standard) of the following composition:
–    Three 95 mm2 (F) flexible copper conductors .
–    50 mm2 protective conductor (provision "c", section 5.1).
–    Three 2.5 mm2 pilot conductors –    .
Ethylene propylene insulation (D).
–    Outer cover of polychloroprene or similar (N).
–    Nominal cable voltage U0/U = 0.6/1 kV.

DN/3E 0.6/1 kV (3x95+ 3x50/3E+ 3x2.5 P) F

g)    Designation of a flexible cable (see UNE 22513-1 Standard) of the following composition:
–    Three 25 mm2 (F) flexible copper conductors .
–    Protective conductor (provision "d", section 5.1) based on three 10 mm2 conductors – Ethylene. propylene insulation (D).
–    Individual shielding (S1) of the insulated main conductors, provided with 1.5 mm2 drains.
–    Outer cover of polychloroprene or similar (N).
–    Nominal cable voltage U0/U = 0.6/1 kV.

DS1N 0,6 /1 kV (3x25+ 3x10+ 3x1,5 D) F

h)    Designation of a flexible cable (see UNE 22513-3 Standard) of the following composition:
–    Three 35 mm2 (F) flexible copper conductors .
–    Protective conductor divided into two 10 mm2 conductors (provision "e", section 5.1).
–    A 10 mm2 pilot conductor    .
–    Insulation (of the main conductors and the pilot conductor) of ethylene propylene (D).
–    Individual shielding (S1) of the insulated main conductors.
–    Outer cover of polychloroprene or similar (N).
–    Nominal cable voltage U0/U = 0.6/1 kV.

DS1N(A) 0,6/1 kV (3x35+ 2x10+ 1x10 P) F






You are not allowed to view links. Register or Login