BS 6387 Category Z

Started by Kalliope Taciarchai, February 28, 2015, 01:33:57 PM

Previous topic - Next topic

Kalliope Taciarchai



BS 6387 Category Z

Test set-up The cable is fixed on a positioning board and flame is applied from below. The positioning board is subjected to 2 knocks every minute during the burn period.

Flame temperature

950 °C ± 40 °C

Test duration 15 minutes

Compliance criterion

It must be possible to transmit power or signals through all conductors while the flame is applied. There must be no short circuit between the conductors or to the shield.