ISO4589-3/BS2782.1 (Temperature Index TI)

Started by cabledatasheet, February 17, 2013, 05:36:15 PM

Previous topic - Next topic

cabledatasheet

ISO4589-3/BS2782.1 (Temperature Index TI)



This is a test for assessing the performance of a material when it is tested in accordance with BS2782 Part 1 Method 143A and 143B. The oxygen index of a material will drop when the temperature rises. When the temperature rises and the oxygen index drops to 21%, the material will burn automatically. This temperature is defined as temperature index. For example, the temperature index of coal is 50%. When the temperature climbs to 150℃, its oxygen index drop to 21% and the coal will burn by itself automatically. The temperature index of the coal will then be defined as 150 ℃. In general, the temperature index of LSZH cables ranges from 250 ℃ to
300℃.

Document echo ' ';