CableDataSheet, Cable and Wire Technical Consulting Service

Technical Paper => General Cable Information => Topic started by: Senghor Tongaat on December 23, 2014, 01:20:53 PM

Title: Implementation of IEC 61196-1 Shielded Screening Attenuation Test Method
Post by: Senghor Tongaat on December 23, 2014, 01:20:53 PM
(https://dm2304files.storage.live.com/y2pVBRACX4mzSY7tp3CBMafRXybC-hhKjfexd2TH56PKAejRfKHoeytIO1q1V56Fp_XXmGoT98CAuAPEeUT7uPFjK7FZeMe_UPlDk_PXVcBLNA/IWCS-1998.pdf.jpg?psid=1&ck=0&ex=720)

Implementation of IEC 61196-1 Shielded Screening Attenuation Test Method

ABSTRACT

The physical design and electrical characteristics of coaxial cable screening attenuation (shield effectiveness) test fixtures, which meet the guidelines of IEC 61196-11 , are presented. Two test fixtures are considered: one for large diameter cable (for example RG-6 type CATV cable) with an upper frequency limit greater than 2 GHz and another for smaller diameter cable with an upper frequency limit greater than 4 GHz. The test procedure is reviewed. Advantages and limitations are discussed. Screening attenuation performance results for a selection of coaxial cable are presented.

https://onedrive.live.com/view.aspx?cid=A212A7DB96D6B5B0&resid=A212A7DB96D6B5B0!1716&app=WordPdf