EN 50305-9.2 / NF F63-305-9.2 Toxicity of the combustion gases

Started by Kalliope Taciarchai, February 28, 2015, 01:53:28 PM

Previous topic - Next topic

Kalliope Taciarchai



EN 50305-9.2 / NF F63-305-9.2 Toxicity of the combustion gases

Test set-up The individual non-metallic components of the cables are burnt in a test chamber.

The toxicity of the fire gas is determined analytically covering 5 substances.

Flame temperature

800 ± 10 °C

Test duration 20 min

Compliance criterion

The toxicity index of the non-metallic components of the cable are calculated according to their proportion of the total mass of the burned gases.