DIN VDE 0815/ 816 Code Designation

Started by Quentin Beauvilliers, October 09, 2014, 09:43:16 AM

Previous topic - Next topic

Quentin Beauvilliers

DIN VDE 0815/ 816 Code Designation



Bennu Meer

A  Basic Types
A-   -
Outdoor telephone cables
S-   -
Switchboard cables
J-   - Installation cables
JE-  - Fire Alarm cables
AJ-  - Outdoor cable with protection against inductive
influences
T-   - Terminating cable
B  Insulation Types
02Y - Cellular PE
2Y - Solid PE
02YS - Foam Skin Insulating cover of cellular PE with
            additional skin of solid polyolefine.
Y - PVC
H - LSZH
C  Filling
F - Petroleum jelly filling
Blank - Unfilled
D  Screening Material
(St) - Static shield of plastic-backed aluminum Tape for 
         indoor cables
D - Shield of copper wire whipping over one stranding
      element (e.g. pair)
LR - Corrugated alumnium tape
Blank - No screen
E  Bedding Material
2Y - PE
Y - PVC
H - LSZH
M - Lead Sheath
MZ - Special  Alloyed Lead Sheath
Blank - No Bedding
F  Armouring Material
b - Armouring
SR - Corrugated steel tape
T - Messenger of galvanized steel wires.
Blank - No Armour
G  Sheath Material
2Y - PE
Y - PVC
H - LSZH
(L)2Y - Laminated sheath (shield of PE coated aluminium
            tape bonded with PE sheath).
M - Lead Sheath
MZ - Special Alloyed Lead Sheath
Blank - No Sheath
H  Number of Pairs/Quads
2x2 - 2 Pairs
2x4 - 2 Quads
I  Conductor Size
0.4 - 0.4mm
0.5 - 0.5mm
0.6 - 0.6mm
0.8 - 0.8mm
0.9 - 0.9mm
J  Stranding Element
PiC - Pairs shielded with copper braid
PiMF - Pairs shielded with aluminium/polyester tape
St - Star Quad(Phantom)
StI - Star Quad(trunk cable)
StIII - Star Quad (local cable)
TIC - Triple shielded with copper braid
TiMF - Triple shielded with aluminium/polyester tape
K  Cable Type
S - Railway signaling cable
L  Types of Stranding
Lg - Stranded in layers
Bd - Unit Type stranding

Tacettin İKİZ


Complete Custom Cable Designation System (A–L)

A. Basic Cable Type

A-Outdoor telephone cables
S-Switchboard cables
J-Installation cables
JE-Fire alarm cables
AJ-Outdoor cable with inductive protection
T-Terminating cable

B. Insulation Type

02YCellular PE
2YSolid PE
02YSFoam-skin (cellular PE + solid polyolefin skin)
YPVC
HLSZH

C. Filling

FPetroleum jelly filled
(blank)Unfilled

D. Screening Material

(St)Static shield (Al/PET tape)
DCopper wire screen on one element (e.g. pair)
LRCorrugated aluminium tape
(blank)No screen

E. Bedding Material

2YPE
YPVC
HLSZH
MLead sheath
MZSpecial alloyed lead
(blank)No bedding

F. Armouring Material

bArmouring
SRCorrugated steel tape
TMessenger wire (galvanized steel)
(blank)No armour

G. Sheath Material

2YPE
YPVC
HLSZH
(L)2YLaminated Al/PE bonded sheath
MLead sheath
MZSpecial alloyed lead
(blank)No sheath

H. Number of Pairs/Quads

2x22 pairs
2x42 quads

I. Conductor Size
You are not allowed to view links. Register or Login