DIN 76722 code designation

Started by Tyne Bowbrick, September 15, 2022, 06:40:49 PM

Previous topic - Next topic

Tyne Bowbrick

 
                                                                                                                                                                                                                                                                                 
DIN 76722 code designation
                                                                                                                                                                                                                                                                               



Tacettin İKİZ

FL   : (Fahrzeugleitung: vehicle cable) voltage class A as defined in ISO 6469-3
FHL  : (Fahrzeug-Hochvolt-Leitung: vehicle high-voltage cable) voltage class B as defined in ISO 6469-3
FZL  : (Fahrzeug-Zündleitung: vehicle ignition cable) as defined in ISO 3808

F   : flat cable
Z   : multicore cable with cores that are easily separated
K   : compressed conductor

Al  : aluminium
W   : resistor material
M   : other conductor materials

R       : reduced insulation thickness ("thin wall" as defined in ISO 6722)
U       : ultra-reduced insulation thickness ("ultra-thin wall" as defined in ISO 6722)
S       : special insulation thickness
nocode  : thick-walled insulation ("thick wall" as defined in ISO 6722)

Code Meaning
Y PVC (polyvinyl chloride)
2Y PE (polyethylene)
4Y PA (polyamide)
5Y PTFE (polytetrafluorethylene)
6Y FEP (tetrafluorethylene/hexafluorpropylene)
7Y E-TFE (ethylene/tetrafluorethylene)
9Y PP (polypropylene)
10Y PVDF (polyvinylidene fluoride)
11Y TPE-U (thermoplastic polyurethane, PUR)
12Y PBT (polybutylene terephthalate)
13Y TPE-E (thermoplastic polyester elastomer)
31Y TPE-S (thermoplastic styrol-block-copolymer)
51Y PFA (perfluoroalkoxy alkane)
52Y MFA (perfluoroalkoxy methylvinylether copolymer)
91Y TPE-O (thermoplastic polyolefin elastomer)
NY non-standardized thermoplastics and thermoplastic elastomers

2G SiR (silicone rubber)
3G E/PRa (ethylene propylene rubber)
4G EVM (ethylene vinyl acetate)
5G CR (chloroprene rubber)
53G PE-C (chlorinated polyethylene)
NG non-standardized elastomers

Code Meaning
B foil shielding
C braided shielding, metal
D spiral wire (or served) shielding, metal
G braid, nonmetallic
L lacquering

Code Meaning
A symmetrical structure as specified in ISO 6722 (all parts)
B asymmetrical structure as specified in ISO 6722 (all parts)
C asymmetrical structure as specified in ISO 6722 (all parts), with finestrands
Sn tin-coated wire surface
Ni nickel-coated wire surface
Ag silver-coated wire surface


You are not allowed to view links. Register or Login

Tacettin İKİZ

You are not allowed to view links. Register or Login

Tacettin İKİZ

The cable designations are based on DIN 76722.
Example 1:
Designation for an unshielded low-voltage cable (FL) with thin-walled insulation (R), code for radia‐
tion cross-linked PE insulation material (2X) as per DIN 76722, a nominal conductor cross section
of 1.5 mm2 (1,5), (/), a maximum strand diameter of 0.33 mm (0,33), with tinned strands (Sn), a
cable composition of type A (-A), and a maximum long-term service temperature Tmax = +125 °C
(T125):
FLR2X 1,5/0,33Sn-A T125
Example 2:
Designation for an unshielded low-voltage cable (FL), code for silicone insulation material (2G) as
per DIN 76722, a nominal conductor cross section of 35 mm2 (35), (/), with bare strands of max.
0.21 mm (0,21), a cable composition of type B (-B), and a maximum long-term service temperature
Tmax = +200 °C (T200):
FL2G 35/0,21-B T200