• Welcome to CableDataSheet, Cable and Wire Technical Consulting Service.
 

News:

You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
Tacettin İKİZ



Main Menu

Def-St. 02-713 (formerly NES 713)/VG 95218-2 Method 1

Started by Ganimedes Reveley, December 29, 2014, 01:36:12 PM

Previous topic - Next topic

Ganimedes Reveley



Def-St. 02-713 (formerly NES 713)/VG 95218-2 Method 1

Test set-up
The individual non-metallic components of the cables are burnt in a test chamber. The toxicity of the fire gas is determined analytically covering 1 substances.

Flame temperature
1150 °C ± 50 °C

Test duration
5 minutes

Compliance criterion
The toxicity readings of the individual non-metallic components of the cable are added according to their proportion of the total volume. The toxicity index for the overall cable must not exceed 5.

You are not allowed to view links. Register or Login


Document echo ' ';