• Welcome to CableDataSheet, Cable and Wire Technical Consulting Service.
 

News:

You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
Tacettin İKİZ



Main Menu

What is the test for power factor and permittivity for cables ?

Started by Lolita Syiny Dobekreo, September 02, 2022, 10:03:11 AM

Previous topic - Next topic

Lolita Syiny Dobekreo

 
                                                                                                         

What is the test for power factor and permittivity for cables ?

Take samples of core of length not less than 5 m, from the complete cable and immerse them in water for 24 h at room temperature with a length of about 250 mm at each end of the core projecting above the water. Measure the power factor and capacitance of the insulation between the conductor and the water with suitable equipment at any convenient frequency between 40 Hz and 62 Hz, at the rated voltage to earth, Uo, of the cable and at a temperature 20 ± 1 °C.



Source : bs 6469-99



Document echo ' ';