What is the Partial Discharge (PD) test and Why is the important for cables?

Started by tacettin, January 21, 2023, 06:39:45 PM

Previous topic - Next topic

tacettin



What is the Partial Discharge (PD) test and Why is the important for cables?

Partial Discharge (PD) test for cables is a non-destructive method of testing that is used to detect and locate any defects or imperfections within the insulation of the cable. The test is performed by applying a high voltage to the cable and measuring any electrical discharges that occur within the insulation. These discharges, or PD, can be caused by a variety of factors, such as manufacturing defects, damage during installation, or degradation of the insulation over time.

Partial Discharge (PD) testing is important for cables because it helps to detect and locate any defects or imperfections within the insulation of the cable. These defects can occur due to a variety of factors, such as manufacturing defects, damage during installation, or degradation of the insulation over time.

If left undetected, PD can lead to a number of problems, such as:

*Reduced electrical power transmission efficiency
*Increased energy consumption
*Equipment failure
*Corrosion of metal components
*Fire hazards
*Reduced service life of the cable

For example, in a high voltage power cable, if there is a small defect in the insulation, PD can occur at that location, which can lead to a gradual deterioration of the insulation. Over time, this can lead to a complete breakdown of the insulation, resulting in a power outage or even a fire. By performing PD testing, these defects can be detected and repaired before they cause more serious problems.

Furthermore, PD testing can also help to extend the service life of cables by identifying defects early on, and taking appropriate measures to address them. PD testing is a non-destructive method of testing, which means that it does not damage the cable during testing, so it can be done periodically to ensure the cable remain in good condition.



How do we test?

1 / Prepare the cable for testing: The cable should be cleaned and dried, and any metal parts should be grounded to prevent interference. Access to both ends of the cable is also needed.

2 / Set up the PD testing equipment: The PD testing equipment typically includes a high voltage power supply, a PD detector, and a data acquisition system. The equipment should be calibrated and verified prior to testing.

3 / Apply high voltage to the cable: The high voltage is applied to the cable using the power supply. The voltage is typically increased in increments, allowing for PD activity to be monitored at each step.

4 / Measure and record PD activity: The PD detector is used to detect and measure PD activity within the cable. The data is then recorded and analyzed.

5 /Locate the PD source: By analyzing the data, the PD source can be located along the cable. This is usually done by measuring the time delay between the application of the voltage and the detection of the PD activity.

6 / Evaluate the PD activity: The PD activity is evaluated to determine the severity of the problem and to identify the cause of the PD.

7 / Report the results and make recommendations: A report is prepared that summarizes the results of the testing and makes recommendations for further action.

8 / Repair or replace the cable if necessary: If the PD activity is found to be significant, the cable should be repaired or replaced to prevent further damage and to ensure safe and reliable operation.

It's worth mentioning that PD testing can be done in a few different ways. The above steps describe the most common method of PD testing, which is known as pulsed DC testing. Other methods include AC testing, impulse testing, and frequency domain testing. Each method has its own advantages and disadvantages, and the choice of method will depend on the specific application and the equipment available.

Source : You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login